Catio Guides & Advice

Catio Instructions

07 June 2026 By Steve Mitchell Catio
Back to Catio Guides & Advice
|Steve Mitchell
4MyPet three-sided catio installed against a house with a waterproof roof

Catio Self-Installation Guide

Thank you for purchasing your catio from 4mypet. Your catio is manufactured in individual timber-framed mesh panels which are screwed together on site to form a secure square or rectangular enclosure.

Depending on the option purchased, your catio will be supplied with either mesh roof panels or clear waterproof roof panels.

Please read this guide fully before starting the installation.

Important Information Before You Begin

Installing a catio requires reasonable DIY experience. The finished enclosure must be level, square, securely fixed and safe for your cats.

We supply the screws required to connect the catio panels together. We do not normally supply the fixings used to attach the catio to your property.

Wall construction varies considerably, including brick, block, concrete, timber, cladding and rendered walls. The installer must inspect the wall and select suitable heavy-duty screws, bolts, plugs or anchors for that particular surface.

If you are unsure which wall fixings to use, please obtain advice from an experienced builder, fitter or reputable fixing supplier before starting.

Tools and Materials You May Need

The exact tools required will depend on the installation area and wall construction. You will normally need:

  • Cordless drill and suitable drill bits
  • Screwdriver or impact driver
  • Spirit level
  • Tape measure
  • Pencil or marker
  • Suitable wall plugs, screws, bolts or anchors
  • Timber or plastic packing pieces
  • Step ladder
  • Adjustable spanner or socket set, where bolts are used
  • Exterior-grade sealant, where required
  • A second person to help hold the panels safely

Large panels and roof sections should not be installed by one person.

1. Prepare the Installation Area

The area must be completely cleared before installation begins. Remove furniture, plant pots, ornaments, waste, branches and any other items that could obstruct the installation.

Check that:

  • The ground or patio is firm and suitable.
  • There are no drains, pipes or cables in the fixing areas.
  • Doors, windows, vents and access points can still operate correctly.
  • The wall is strong enough to support the catio.
  • There is sufficient access to safely fit the roof panels.

Most patios and paved areas slope away from the house to allow rainwater to drain. This means the bottom of the catio panels may need to be packed underneath so that the enclosure remains level.

Do not simply follow the slope of the patio, as this can cause the panels, doors and roof to become misaligned.

2. Identify and Lay Out the Panels

Before fixing anything, lay the panels out on the ground in their approximate positions.

Check that you have the correct panels for:

  • The left-hand side
  • The right-hand side
  • The front of the enclosure
  • The entrance door
  • The roof

Compare the panel sizes with your order or supplied drawing.

The two side sections will normally extend out from the property wall. The front panels will then connect the two sides together to complete the enclosure.

Do not begin drilling into the property until you are satisfied that every panel is present and positioned correctly.

3. Position the First Side Panel

Start with one of the side panels that will be fixed directly against the property.

Place the panel in its intended position and use a spirit level to check that it is completely upright in both directions.

House walls are not always perfectly straight or flat. It may be necessary to place suitable packing pieces between the timber frame and the property wall so that the panel remains upright.

Mark the required fixing positions through the timber frame.

Before drilling, check carefully for hidden electrical cables, water pipes, gas pipes or other services.

Drill the wall and securely fix the first panel using appropriate heavy-duty wall fixings. Do not overtighten the fixings, as this may pull the panel out of level or damage the timber.

Recheck the panel with a spirit level after tightening.

4. Build the First Side

Continue adding the remaining side panels, working outwards from the property.

Use the screws supplied to connect the timber frames together. The panel edges should sit neatly against one another without large gaps.

Before fully tightening the screws, check that each panel is:

  • Upright
  • Level
  • In line with the previous panel
  • Sitting securely on the ground or suitable packing

It is normally best to fit the screws loosely at first, make any necessary adjustments and then tighten them once the panels are correctly aligned.

5. Build the Opposite Side

Repeat the same process on the opposite side of the enclosure.

Fix the first panel securely to the property using suitable wall fixings, ensuring it is upright and correctly positioned.

Build the remaining panels outwards until both sides are complete.

Measure the distance between the two sides at several points. The distance at the property, the centre and the front should be consistent unless your supplied drawing shows otherwise.

6. Fit the Front Panels

Once both sides are positioned correctly, begin fitting the front panels.

Connect the front panels to one side and work across towards the opposite side. Check regularly that the complete enclosure remains square.

You can check for square by measuring diagonally from corner to corner. When both diagonal measurements are equal, the enclosure is square.

Do not force the final panel into position. If it does not fit correctly, recheck:

  • The spacing between the side panels
  • Whether the panels are upright
  • Whether the base is level
  • Whether packing is required
  • Whether the enclosure is square

Small alignment adjustments made throughout the installation are much easier than trying to correct the complete enclosure at the end.

7. Fit and Check the Door

Fit the door panel in the position shown on your drawing or order.

Before fitting the roof, open and close the door several times.

The door should:

  • Open without catching the ground
  • Close evenly against the frame
  • Remain square within the opening
  • Latch securely
  • Have an even gap around the edges

If the door catches or does not close correctly, this normally means that part of the enclosure is not level, upright or square. Adjust the panels or packing before continuing.

Do not trim or alter the door until the complete enclosure has been checked for level and square.

8. Fit a Mesh Roof

Where mesh roof panels have been purchased, place the roof panels onto the top of the completed enclosure.

Check that each roof panel is correctly supported by the side and front frames. Screw the roof panels securely to the timber framework using the supplied screws.

Make sure there are no unsecured edges or gaps that a cat could push through.

Do not climb or place your full body weight onto the roof panels.

9. Fit a Waterproof Roof

A waterproof roof requires particular care. It must have a suitable fall so rainwater runs off rather than collecting on top.

The roof should normally fall away from the property unless your supplied design states otherwise.

Before fixing the waterproof roof panels, check that:

  • The supporting roof framework is level from side to side.
  • The roof has a continuous fall in the correct direction.
  • The panels are supported correctly.
  • Water will not run towards the property.
  • There are no low areas where water could pool.

Patio slopes and uneven walls can affect the roof angle. Additional packing or adjustment may be required to achieve the correct fall.

Water pooling can damage the roof panels and timber framework and may cause leaks. Do not fit a waterproof roof completely flat.

Ensure all waterproof roof panels overlap in the correct direction and use suitable washers, fixings and seals where supplied.

Do not overtighten fixings through clear roof sheets, as this may crack or distort the material.

10. Final Safety Checks

Before allowing your cats into the enclosure, inspect the complete catio carefully.

Check that:

  • All panel connection screws are fitted and tight.
  • All wall fixings are secure.
  • The enclosure is upright, level and square.
  • The door opens, closes and locks correctly.
  • All roof panels are securely fixed.
  • There are no gaps around the wall, roof or ground.
  • No sharp screw points or fixings are exposed.
  • The mesh has not been damaged during installation.
  • Any shelves, ladders or accessories are securely attached.
  • Waterproof roof panels have the correct fall.
  • The enclosure cannot move when gently pushed.

Any gaps around an uneven wall should be safely closed using suitable timber packing, mesh or another secure exterior-grade material.

Ongoing Maintenance

Timber structures naturally move slightly as weather conditions change. Check the enclosure regularly, particularly after strong winds or severe weather.

We recommend checking:

  • Wall fixings
  • Panel screws
  • Door alignment and latches
  • Roof fixings
  • Mesh condition
  • Timber condition
  • Waterproof seals
  • Any ground-level gaps

Retighten fixings where required and replace any damaged components before allowing your cats to use the enclosure.

Important Safety Notice

This guide provides general installation information only. Every property and installation area is different.

The person carrying out the installation is responsible for assessing the wall, ground, required fixings and overall safety of the completed enclosure.

If you are not confident that you can install the catio securely, we strongly recommend using an experienced installer or selecting our professional fitting service.